Troubleshooting ignition

Jump to: navigation, search
m
Line 11: Line 11:
 
This step checks for proper points or electronic module operation.  
 
This step checks for proper points or electronic module operation.  
  
2A --  For a quick test : Dist' cap off , ignition on , points open , use test light to check for power at moveable contact and ground at stationary contact . This must be with point type ignition for it to work  
+
2A --  For a quick test : Dist' cap off , ignition on , points open , use test light to check for power at moveable contact and ground at stationary contact . This must be with point type ignition for it to work  
  
 
2B -- Using the same test light, check the negative side of the coil while cranking; the light should flash. If it does then the points or module are working. If the light stay lit constant then the points are not closing or the electronic module is defective or the distributor ground is missing
 
2B -- Using the same test light, check the negative side of the coil while cranking; the light should flash. If it does then the points or module are working. If the light stay lit constant then the points are not closing or the electronic module is defective or the distributor ground is missing

Revision as of 19:08, 26 August 2010

Personal tools
Namespaces
Variants
Actions
Navigation
Categories
Toolbox